Henry Weller authored
Select LTS via the ddtScheme: ddtSchemes { default localEuler rDeltaT; } The LTS algorithm is currently controlled with the standard settings in controlDict, e.g.: maxCo 0.5; maxDeltaT 2e-8; with the addition of the optional rDeltaT smoothing coefficient: rDeltaTSmoothingCoeff 0.02; which defaults to 0.02. ddtSchemes { default localEuler rDeltaT; }