Skip to content
  • Will Bainbridge's avatar
    twoPhaseMixtureThermo: Fix for collated file operation · 70bc72c2
    Will Bainbridge authored
    twoPhaseMixtureThermo writes the temperatures during construction only
    for them to be read again immediately after by construction of the
    individual phases' thermo models. When running with collated file
    handling this behaviour is not thread safe. This change deactivates
    threading for the duration of this behaviour.
    
    Patch contributed by Mattijs Janssens
    70bc72c2