Commit 341bdc8a authored by Henry's avatar Henry
Browse files

Corrected docs

Resolves bug-report http://www.openfoam.org/mantisbt/view.php?id=1658
parent 5a12edc3
...@@ -73,7 +73,6 @@ primitives/triad/triad.C ...@@ -73,7 +73,6 @@ primitives/triad/triad.C
/* functions, data entries */ /* functions, data entries */
primitives/functions/DataEntry/makeDataEntries.C primitives/functions/DataEntry/makeDataEntries.C
primitives/functions/Polynomial/polynomialFunction.C primitives/functions/Polynomial/polynomialFunction.C
primitives/subModelBase/subModelBase.C primitives/subModelBase/subModelBase.C
......
...@@ -39,9 +39,9 @@ Description ...@@ -39,9 +39,9 @@ Description
where: where:
\vartable \vartable
h | heat transfer coefficient [W/m2/K] h | heat transfer coefficient [W/m^2/K]
Ta | ambient temperature [K] Ta | ambient temperature [K]
q | heat flux [W/m2] q | heat flux [W/m^2]
\endvartable \endvartable
The thermal conductivity, \c kappa, can either be retrieved from the The thermal conductivity, \c kappa, can either be retrieved from the
...@@ -52,11 +52,11 @@ Description ...@@ -52,11 +52,11 @@ Description
\heading Patch usage \heading Patch usage
\table \table
Property | Description | Required | Default value Property | Description | Required | Default value
kappa | thermal conductivity option | yes | kappa | thermal conductivity option | yes |
q | heat flux [W/m2] | yes* | q | heat flux [W/m^2] | yes* |
Ta | ambient temperature [K] | yes* | Ta | ambient temperature [K] | yes* |
h | heat transfer coefficient [W/m/K] | yes*| h | heat transfer coefficient [W/m^2/K] | yes*|
thicknessLayers | list of thicknesses per layer [m] | yes | thicknessLayers | list of thicknesses per layer [m] | yes |
kappaLayers | list of thermal conductivites per layer [W/m/K] | yes | kappaLayers | list of thermal conductivites per layer [W/m/K] | yes |
kappaName | name of thermal conductivity field | yes | kappaName | name of thermal conductivity field | yes |
......
...@@ -27,14 +27,14 @@ Class ...@@ -27,14 +27,14 @@ Class
Description Description
Fixed heat boundary condition to specify temperature gradient. Input Fixed heat boundary condition to specify temperature gradient. Input
heat source either specified in terms of an absolute power [W], or as a heat source either specified in terms of an absolute power [W], or as a
flux [W/m2]. flux [W/m^2].
Example usage: Example usage:
hotWall hotWall
{ {
type compressible::turbulentHeatFluxTemperature; type compressible::turbulentHeatFluxTemperature;
heatSource flux; // power [W]; flux [W/m2] heatSource flux; // power [W]; flux [W/m^2]
q uniform 10; // heat power or flux q uniform 10; // heat power or flux
kappa fluidThermo; // calculate kappa=alphaEff*thermo.Cp kappa fluidThermo; // calculate kappa=alphaEff*thermo.Cp
Qr none; // name of the radiative flux Qr none; // name of the radiative flux
......