    Hi,

    In some situation, you have to run renumberMesh twice in the same workflow. For example, if you run a coarse case, map to a fine mesh and run it. This leads to a error message:

    Reading volScalarField cellID [3] [3] [3] --> FOAM FATAL IO ERROR: [3] size 58624 is not equal to the given value of 58185 [3] [3] file: /home/a45bwpq/OpenFOAM/1606+/a45bwpq-16.06plus/tutorials/incompressible/simpleFoam/motorBike/processor3/constant/cellID from line 18 to line 58953. [3] [3] From function Foam::Field::Field(const Foam::word&, const Foam::dictionary&, Foam::label) [with Type = double; Foam::label = int] [3] in file /appl/openfoam/16.06plus/OpenFOAM-16.06plus/src/OpenFOAM/lnInclude/Field.C at line 295. [3] FOAM parallel run exiting

    motorBike test case is attached to reproduce the error.

    Best, Sebastien