reference FO : pre-2112 behaviour
With develop branch, reference FO needs mandatory entry refValue
which was not present in earlier versions.
So to upgrade to 2112,
- with position : set
refValue sample
and your entry for position - without providing position keyword : set
refValue zero
(assuming you don't want to provide any offset)- Optionally one can think of using
multiply
FO instead
- Optionally one can think of using