    BUG: Fix issue 1535 in turbulentTemperatureRadCoupledMixed. · 0ff95341
    sergio authored
    When a contact resistance is used the T field on each coupled
    patch is different due to the thermal resistance. Thus, instead
    of solving for a unique Tw at the wall, we solve for Tw1 at one side
    then, the Tnbr internal becomes Tw2, which is the T of the nbr patch.
    0ff95341
    BUG: Fix issue 1535 in turbulentTemperatureRadCoupledMixed.
    sergio authored
    When a contact resistance is used the T field on each coupled
    patch is different due to the thermal resistance. Thus, instead
    of solving for a unique Tw at the wall, we solve for Tw1 at one side
    then, the Tnbr internal becomes Tw2, which is the T of the nbr patch.