Skip to content
Snippets Groups Projects
  • Andrew Heather's avatar
    bb04f575
    ENH: runTimeControl - enable resetting the trigger to an earlier instant · bb04f575
    Andrew Heather authored and Mark OLESEN's avatar Mark OLESEN committed
    The runTimeControl function object can activate further function objects using
    triggers. Previously the trigger index could only advance; this change set
    allows users to set smaller values to enable function object recycling, e.g.
    
    Repeat for N cycles:
    1. average the pressure at a point in space
    2. when the average stabilises, run for a further 100 iterations
    3. set a new patch inlet velocity
      - back to (1)
    
    - Removes old default behaviour that only permitted an increase in the
      trigger level. This type of 'ratcheting' mechanism (if required) is
      now the responsibility of the derived function object.
    bb04f575
    History
    ENH: runTimeControl - enable resetting the trigger to an earlier instant
    Andrew Heather authored and Mark OLESEN's avatar Mark OLESEN committed
    The runTimeControl function object can activate further function objects using
    triggers. Previously the trigger index could only advance; this change set
    allows users to set smaller values to enable function object recycling, e.g.
    
    Repeat for N cycles:
    1. average the pressure at a point in space
    2. when the average stabilises, run for a further 100 iterations
    3. set a new patch inlet velocity
      - back to (1)
    
    - Removes old default behaviour that only permitted an increase in the
      trigger level. This type of 'ratcheting' mechanism (if required) is
      now the responsibility of the derived function object.