The runTimeControl function object can activate further function objects using triggers. Previously the trigger index could only advance; this change set allows users to set smaller values to enable function object recycling, e.g. Repeat for N cycles: 1. average the pressure at a point in space 2. when the average stabilises, run for a further 100 iterations 3. set a new patch inlet velocity - back to (1) - Removes old default behaviour that only permitted an increase in the trigger level. This type of 'ratcheting' mechanism (if required) is now the responsibility of the derived function object.