- May 16, 2018
-
-
Mark OLESEN authored
- tie the MPI rules to the base compiler type *without* its version. Eg, linux64Gcc (which exists) instead of linux64Gcc81
-
- May 02, 2018
-
-
mattijs authored
-
- Apr 11, 2018
-
-
Mark OLESEN authored
- was using st_atim instead of st_mtim for the nanoseconds - value of followLink was being ignored (it was always being followed).
-
- Apr 06, 2018
-
-
sergio authored
This thermo is used with multiComponentMixture in rhoThermo type
-
- Mar 21, 2018
-
-
- occurred when the initial mesh distribution was missing cells on some processors.
-
- Mar 20, 2018
-
-
Andrew Heather authored
-
- Mar 19, 2018
-
-
Andrew Heather authored
-
- Mar 14, 2018
-
-
Andrew Heather authored
-
- Mar 13, 2018
-
-
Mark OLESEN authored
- using const reference to temporary was failing. Remedy by using a direct copy, which is a reasonable solution since surfZone content is quite minimal.
-
Andrew Heather authored
-
Andrew Heather authored
-
- Feb 28, 2018
-
-
Mark OLESEN authored
-
Mark OLESEN authored
-
- Feb 23, 2018
-
-
Mark OLESEN authored
-
Andrew Heather authored
The minimum number of particles per parcel can now be set in the injection model input, e.g.: model1 { type ...; massTotal ...; parcelBasisType ...; minParticlesPerParcel 1; <-- new optional entry SOI ...; ... Uses a value of 1 by default if the entry is not present. The value of 1 is generally recommended and beneficial for coupled cases where small time steps can lead to the injection of too many parcels and subsequently greatly over-predict the particle source contributions (momentum, heat, mass transfer etc)
-
- Jan 25, 2018
-
-
sergio authored
-
sergio authored
The non-dimensional table takes non-dimensional U as entry, not flow rate
-
Andrew Heather authored
-
- Jan 24, 2018
-
-
Mark OLESEN authored
- runTimeModifiable change to the dictionary not being propagated to the underlying functionObjects
-
- Jan 23, 2018
-
-
Mark OLESEN authored
- problems when the cloud was not available on all processors. - NB: ensight measured data only allows a single cloud, but foamToEnsight writes all clouds.
-
- Jan 19, 2018
-
-
Andrew Heather authored
-
- Jan 18, 2018
-
-
Andrew Heather authored
-
Andrew Heather authored
-
- Jan 17, 2018
-
-
Mark OLESEN authored
- these were previously taken from region-local directories (eg, constant/region/triSurface), but this becomes difficult to manage when there are many files and regions.
-
Mark OLESEN authored
- The central InfoSwitch "writeLagrangianPositions" allows writing an additional Lagrangian "positions" file, but these were not being written by reconstructPar. These are now also written in reconstructPar if the central writeLagrangianPositions InfoSwitch is enabled. NOTES - "positions" are reconstructed from the processors "coordinates" file - decomposePar will not attempt to create or redistribute any "positions" files
-
- Jan 11, 2018
-
-
Andrew Heather authored
-
- Jan 10, 2018
-
-
mattijs authored
-
- Jan 08, 2018
-
-
Andrew Heather authored
-
- Jan 05, 2018
-
-
Andrew Heather authored
-
- Dec 29, 2017
-
-
Andrew Heather authored
-
Andrew Heather authored
switch The new lowReCorrection entry can be used to ensure that the low-Re mode is only applied when its value is on/true, e.g. lowReCorrection on; When active, the low-Re mode is active when the local y+ is less than the calculated y+_laminar. When inactive, the high-Re form is employed irrespectively of the local y+. It has a defaulrt value of off/false for backwards compatibility with OpenFOAM v1706
-
- Dec 28, 2017
-
-
mattijs authored
-
- Dec 27, 2017
-
-
mattijs authored
-
- Dec 26, 2017
-
-
Andrew Heather authored
-
- Dec 22, 2017
-
-
-
Andrew Heather authored
Computes the heat transfer coefficient [W/m2/K] using a run-time selectable model: - ReynoldsAnalogy - fixedReferenceTemperature - localReferenceTemperature
-
Andrew Heather authored
-
Andrew Heather authored
-
Andrew Heather authored
-
- Dec 21, 2017
-
-
sergio authored
NOTE: The radiative flux (qr) is positive when the heat flux is going into the wall, this is oposite the the he flux which is positive going out of the wall.
-